Plasticizing Screw
The professional design of screw assembly ensures uniform plastic melt density and repeatable physics and weight of products
|
|
Screw Tip Assembly High-hardness plated screw tip assembly makes the residue easy to clean, the products less black spots and impurities, and the screw more corrosion-resistant. |
|
Centering Bearing for Injection Table The unique injection structure with one extra centering bearing on the basis of standard positioning bearing , enhances the positioning of plasticizing, reduces the radial runout of the screw during plasticizing, further, improves the resistance of screw component & the durability of bearing.
|
– OTHER SYSTEMS –
Linear Guide | Clamping Toggles | |
The injection position achieves a repeatable accuracy of up to 0.1mm. (Tested under standard conditions in the factory) The injection table has linear guides with a thickened frame, allowing minimum movement resistance and high-speed injection response. |
Strengthened three molding platens, with the center-force design and finite element force analysis, optimize the mechanical curve of clamping toggles to enhance the speed and precision of mold opening and closing. | |
Clamping Unit | Large-Diameter Oil Circuit | |
Strictly check the parallelism between the fixed and moving platen and the withstand of clamping force consistency for four tie bars. We rigorously test the parallelism of the movable and fixed platens and the uniformity of clamping force on four tie bars. |
Adopt a large-diameter oil circuit and a control method with low internal resistance to improve the response tempo and repeat accuracy of injection. |
PET Injection Molding Machines Parameter
Mode | Unit | YZ160S-PET | YZ200S-PET | YZ260S-PET | YZ320S-PET | YZ400S-PET | YZ480S-PET | |
International Standard | 660/1600 | 912/2000 | 1322/2600 | 1992/2600 | 1992/3200 | 2310/4000 | 3695/4800 | |
Injection Unit | ||||||||
Screw Diameter | mm | 52 | 60 | 67 | 75 | 75 | 83 | 90 |
Screw Draw Ratio | L:D | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
Injection Volume | cm³ | 448 | 676 | 973 | 1423 | 1423 | 2028 | 2544 |
PET Injection Weight | g | 520 | 784 | 1129 | 1651 | 1651 | 2352 | 2951 |
OZ | 18.2 | 27.4 | 39.5 | 57.8 | 57.8 | 82.3 | 103.3 | |
Injection Pressure | Mpa | 147 | 135 | 135 | 140 | 140 | 114 | 145 |
Injection Stroke | mm | 211 | 239 | 276 | 322 | 322 | 375 | 400 |
Injection Speed | mm/s | 103 | 106 | 132 | 130 | 130 | 151 | 125 |
Injection Rate | cm³/sec | 218 | 300 | 465 | 573 | 573 | 816 | 796 |
Screw Speed | r/min | 169 | 159 | 169 | 181 | 181 | 147 | 152 |
Clamping System | ||||||||
Clamping Force | KN | 1600 | 2000 | 2600 | 2600 | 3200 | 4000 | 4800 |
Clamping Stroke | mm | 425 | 485 | 540 | 540 | 620 | 720 | 770 |
Max Platen Opening | mm | 925 | 1035 | 1140 | 1140 | 1280 | 1470 | 1590 |
Min-Max Mould Thickness | mm | 160-500 | 180-550 | 195-600 | 195-600 | 220-600 | 250-750 | 275-820 |
Dist. between Tiebars | mm×mm | 460×460 | 510×510 | 575×575 | 575×575 | 655×655 | 760×730 | 810×810 |
Platen Dimension | mm×mm | 670×670 | 765×765 | 840×840 | 840×840 | 940×940 | 1080×1050 | 1155×1155 |
Diameter of Mold Locating Hole | mm | Ø125H8 | Ø160H8 | Ø160H8 | Ø160H8 | Ø160H8 | Ø200H8 | Ø200H8 |
Ejector Force | KN | 67 | 77 | 111 | 111 | 111 | 166 | 166 |
Ejector Stroke | mm | 140 | 150 | 180 | 180 | 180 | 215 | 250 |
Ejector Pin Quantity | pcs | 5 | 5 | 13 | 13 | 13 | 13 | 13 |
Power Unit | ||||||||
Hydraulic System Pressure | Mpa | 17.5 | 17.5 | 17.5 | 17.5 | 17.5 | 17.5 | 17.5 |
Oil Pump Motor | KW | 27 | 32 | 60 | 65 | 65 | 75 | 37+60 |
Heating Power | KW | 14.4 | 19.8 | 23.4 | 30 | 30 | 37 | 42.3 |
Temperature Control Zone | section | 5 | 5 | 5 | 5 | 5 | 6 | 6 |
General | ||||||||
Oil Tank Capacity | L | 230 | 335 | 470 | 470 | 565 | 660 | 760 |
Machine Weight | TON | 5 | 6.6 | 8.9 | 9.1 | 11.6 | 15 | 18.7 |
Overall Dimension (LxWxH) |
m×m×m | 4.9×1.29× 1.97 | 5.61×1.36× 1.94 | 6.46×1.49× 2.06 | 6.65×1.49× 2.06 | 7.02×1.6× 2.18 | 7.77×1.65× 2.15 | 8.74×1.82× 2.19 |